6.4 Coring tool for discrete soil samples -- Disposable 10-mL plastic syringes with the Luer tip and rubber plunger cap removed (modified), or an equivalent metal tube fitted with a plunger. The outer diameter of coring tool should be smaller than the mouth of the VOA vial. Commercial stainless steel samplers fitted with plungers are also
Place the mouth of the sampler into the 40ml VOA vial containing the appropriate preservative and extrude the sample by pushing the plunger down. Quickly place the lid back on the 40ml VOA vial. Note: When capping the 40ml VOA vial, be sure to remove any soil or debris from the top and/or threads of the vial. 4.
Order your VOA vial, Summa Canister, or Terra Core sample testing bottles for air, water, and soil testing from York Lab today.
How to use the Terra Core ® Sampler. Step 1 - Have ready a 40ml glass VOA vial containing the appropriate preservative. With the plunger seated in the handle, push the Terra Core ®. Step 2 - Wipe all soil or debris from the outside of the Terra Core ® sampler. The soil plug should be flush with the mouth of the sampler.
The Terra Core soil sampler delivers an approximate 5g sample quickly and conveniently into a 40mL VOA vial for in-field preservation. Vial threads stay free of debris and and volatile target analytes are better maintained by minimal exposure and handling than manual
Methods 5035/5035A Low-Level Soil VOCs(<= 200 ug/kg) Sample collection options (coring devices): EnCore™ Sampler (or similar devices): Designed to collect and contain/transport a soil core. Sample may be transferred to a 40 ml VOA vial before shipment to lab. Terra Core Sampler™, Powerstop Handle™ and EasyDraw Syringe™ (or similar devices)
GL Soil container ( ) oz 40 ml VOA Vial [ ] As is [ ] HCI GL Amber 1000ml [ ] As is [ ] H2SO4 PL As is [ ] 250ml [ ] 500ml [ ] 1000ml PL H2SO4 [ ] 250ml [ ] 500ml Comments, Special Requirements or Regulations: Sample Matrixx 587 East Middle Turnpike, P.O. Box 370, Manchester, CT 06040 Client Services (860) 645-8726
Halocarbons/BTEX 8010/8020, 8021, 502.2 VOA-glass 2 40ml vials Cool, HCL, no HS* 14 days** Volatiles by GC/MS 8260 VOA-glass 2 40ml vials Cool, HCL, no HS* 14 days** Semi-Volatile Organics (DRO) Diesel Range Organics 8015 VOA-glass 3 40ml vials / 1 2oz Cool 7 days / 14 soil
• *40ml VOA vial with 25ml of methanol • 10ml plastic syringe (with tip clipped off) • Wax paper • Fat and thin tipped waterproof markers such as the Sharpie fine point, the Sharpie extra fine point and/or the Sharpie ultra fine point • PID • Coolers with temperature blanks • Ice • Plastic zip bags
The OI Analytical 4100 Water / Soil Sample Processor automates the handling and processing of samples in 40-mL VOA vials for purge-and-trap analysis of volatile organic compounds (VOCs) in accordance with U.S. EPA methods. The 4100 efficiently processes up to 100 drinking water, wastewater, or soil samples and operates with a single or dual
Apr 01, 2019 · Studies in deionized water without the presence of site soil contained 100-mL liquid in the serum bottles or 40-mL liquid in the VOA vials. Studies with site soil were conducted in VOA vials and contained 5 g of soil and 39 mL of liquid. Reactors were prepared by initially adding DI water, oxidant at various concentrations, and soil if required.
Soil/Sediment/Solid Matrix Organics. * If sampling by method 5030 (not preferred) collect the sample in a 4 oz. glass jar with no headspace then cool to 4ºC. * If sampling by method 5035 (preferred) collect a 5 gram sample for low level analysis in each of 3 – 40ml glass VOA vials with Teflon lined septa then freeze the samples ASAP.
Glass Vials/EPA Vials/VOA Vials; 5035 PrePreserved(R) VIALS; 5035 Soil Sampling Tools; Tedlar(R)/ Gas Sampling Bags ... capsure ® leak proof Bottles.
504.1 EDB/DBCP 280 ml O2-40ml VOA vials -6 C, Na 2 S 2 3 14 days 508 Pesticides S1000 ml 11L amber G 2-6 C, Na 2 2 O 3 7,14 days 515.1 Herbicides 1000 ml 1-1L amber G 2-6 C, Na 2 S 2 O 3 14,28 days 524.2 Volatiles 120 ml 2-40mL VOA vials 2-6 C, ascorbic acid, HCl in field 14 days